Static limiting load diagrams

Static limiting load diagrams

The static limiting load diagrams serve to:
■ Check the selected bearing size under mainly static load
■ Determine the tilting moment MK which the AXRY can support in addition to the axial load.

The static limiting load diagrams take into account the static load safety factor S0 ≥ 4 as well as the screw and bearing ring strength.

Example: Static limiting load diagram for AXRY
1 Bearing/size
2 Permitted range
3 Non-permitted range
MK Maximum tilting moment in [kNm]
Fa Axial load [kN]

Static limiting load diagram for AXRY 120-NGS (NGS-SBI)

Static limiting load diagram for AXRY 200 – 395-NGS (NGS-SBI)

Static limiting load diagram for AXRY 460 – 650-NGS (NGS-SBI)