Nominal life time

Nominal life time

The calculation of the nominal life time takes place via special calculation programs. Should you have questions, please contact myonic application engineering.

Calculations at myonic

The following is required for calculation purposes:
Details on application (drawings, sketches, specifications)
Workpiece dimensions and weight
Details on the load cycle (cutting forces, speeds, operating durations)

Static load safety factor

The calculation of the static load safety factor must be executed separately for the radial and axial bearing parts. The static load safety factor for machine tool application should total So > 4 in order to avoid permanent plastic deformations in the bearing.

S0= C0r/F0r or S0= C0a/F0a

So = static load safety factor
Coa / Cor [N] = static load rating according to table of dimensions
For, Foa [N] = static load of radial or axial bearing section